Blue-White - Chemical metering and fluid measurement solutions; chemical metering pumps, peristaltic pumps, diaphragm pumps, multi-diaphragm pumps, flow meters, flowmeters, variable area flow meters, paddlewheel flow meters, ultrasonic flow meters, engineered skid systems, single skid system, duplex skid system, triplex skid system, water analyzers...
Oswald

Industrial

A4

Product Specifications

Performance for A4S 

Model Tube Tubing Material Feed Rate Max Speed Max Pressure Max Temp 
GPH LPH mL/Min RPM PSI(bar) °F(°C) 
A4-*NH-T Flex-A-Prene .01 – 28.5 .04 – 108 0.7 – 1800 125 125 (8.6) 185 (85) 
A4-*NHL-T Flex-A-Prene .01 – 28.5 .04 – 108 0.7 – 1800 125 65 (4.5) 185 (85) 
A4-*NK-T Flex-A-Prene .02 – 50.7 .08 – 192 1.3  – 3200 125 80 (5.5) 185 (85) 
A4-*NHH-T Flex-A-Prene .02 – 54.0 .09 – 204 1.4 – 3400 125 100 (6.9) 185 (85) 
A4-*NHHL-T Flex-A-Prene .02 – 54.0 .09 – 204 1.4 – 3400 125 65 (4.5) 185 (85) 
A4-*NL-T Flex-A-Prene .04 – 100.0 .15- 378 2.5  – 6300 125 50 (3.4) 185 (85) 
A4-*NP-T Flex-A-Prene .06 – 158.5 .24 – 600 4.0 – 10000 125 30 (2.1) 185 (85) 
A4-*TH-T Flex-A-Chem .01 – 25.4 .04 – 96 0.6- 1600 125 30 (2.1) 130 (54) 
A4-*TK-T Flex-A-Chem .02 – 54.0 .08 – 204 1.4 – 3400 125 30 (2.1) 130 (54) 
A4-*TKK-T Flex-A-Chem .05 – 126 .18 – 477 3.2 – 7950 125 30 (2.1) 130 (54) 
A4-*GH-T Flex-A-Thane .01 – 39.6 .06 – 150 1.0 – 2500 125 65 (4.5) 130 (54) 
A4-*GHH-T Flex-A-Thane .03 – 71.0 .11 – 269 1.9 – 4480 125 65 (4.5) 130 (54) 
A4-*GK-T Flex-A-Thane .02 – 28.5 .09 – 210 1.4 – 3500 125 65 (4.5) 130 (54) 
A4-*GKK-T Flex-A-Thane .04 – 100.0 .20 – 378 2.5 – 6300 125 65 (4.5) 130 (54) 

Fitting connections for A4S pump = * 

“M” = 1/2” Male NPT 

“B” = 1/2” Hose Barb  

“C” = ½” – ¾” Tri-Clamp 

“Q” = Quick Disconnect 

“MB” = 1/2 Male BSPT 

Maximum Viscosity: 5,000 Centipoise 

Maximum Suction Lift: 30 ft at sea level (14.7 atm psi) 

Electrical and Controls 

Electrical Power Requirement:  100 to 240VAC, 50/60Hz 

Motor: Brushless DC, 2,500:1 Turndown, Continuous Duty 

Power cord options available (6 feet length): 

  • 115VAC 50/60HZ, NEMA 5/15 plug  (U.S.) – (choose when specifying pump model) 
  • 220VAC 50/60HZ ,CEE 7/V11 plug (EU) – (choose when specifying pump model) 
  • 230VAC 50/60HZ, NEMA 6/15 (U.S.) – (ordered separately) 
  • 240VAC 50/60HZ, AS 3112 plug (Australia / New Zealand) (ordered separately) 
  • 230VAC 50/60HZ, BS 1363/A plug (UK) (ordered separately) 

Signal Connectors: M12 – 5 pin, IP67 rated connectors 

Inputs: 

  • 4-20 mA – fully configurable  
  • Frequency / Pulse input – fully configurable 
  • Stop/Start Dry Contact Closure (Configurable for N.O. or N.C.) 
  • Auto Prime – Secondary Contact Closure  
  • FVS (Flow Verification System) (Flow sensor provided by others) 

Outputs: 

  • 4-20 mA output – fully configurable 
  • Frequency output (Open collector) 
  • Four (4) Alarm Outputs – Programmable. 

Materials of Construction 

Pump Head: Valox® (PBT) 

Pump Head Cover: Polycarbonate, with permanently sealed motor shaft support bronze sleeve bearing.  

Cover Screws: Stainless steel, polypropylene cap. 

Roller assembly: Rotor – Valox, Rollers – Nylon. 

Motor Shaft: Chrome-Plated Steel 

TFD Sensor: Hastelloy C 

Power Cord: 3 Conductor, SJTW-A water-resistant 

Mounting Brackets: 316 Stainless Steel  (standard and extended) 

Enclosure: NEMA 4X (IP66) Valox 

Tube Fittings: PVDF (part of tube assembly) 

Tube Assembly Options 

Flex-A-Prene® tubing – An excellent material for most water treatment applications. Chemically resistant to 25% Sodium Hypochlorite, 30% Sulfuric Acid, 30% Fluosilicic Acid, Ferric Chloride, Alum and many others. 

Flex-A-Chem® tubing – This material consists of an outer Norprene jacket with an inner liner that is virtually unaffected by acids, bases, salts, ketones, and alcohols.  

Flex-A-Thane® tubing – This polyurethane material can be used with a variety of chemicals, including Oil and Water based Polymers, fuels and lubricants, and many others. 

Flex-A-Prene®, Flex-A-Chem®,  and Flex-A-Thane® tubing comply with FDA 21 CFR, 117.2600 criteria for food processing.  

Dimensions and Weights 

Maximum Overall Dimensions: 12-1/8”W x 15-1/4”H x 16-1/2”D (30.8W x 38.8H x 41.9D cm) 

Product Weight: 45.5 Lb. (20.64 Kg) 

Approximate Shipping Weight:  50 lb. (22.68 Kg) 

Agency Listings 

CE  

cETLus 

RoHS Compliant 

FAQs

Frequently Asked Questions

A4S Specifications

  • What is a Tri-Clamp fitting?

    Tri-Clamp fittings and connections are used primarily in the food and beverage industry for sanitary applications. Tri-Clamp fittings minimize leaks and contamination by providing a better seal between fittings. A complete Tri-Clamp section consists of two ferrule or flanges meeting together with a gasket in between, and a clamp around the outside of the piping/flanges. Tri-Clamp fittings provided on Blue-White tubes will fit both 1/2" and 3/4" Tri-Clamp fittings.

  • How accurate is the analog input? e.g. If I send it 0.1 mA, will the pump read 0.1 mA? Could the pump possible run if I send it 4.0mA?

    The A3, A4, M3, M4 pumps will read 4-20mA signals to a resolution of .05 mA. The pumps will be able to read signals in increments of 0.1 mA. It is possible the pump may not read the exact value of signal being sent from the control/PLC/SCADA, as there can be electrical noise due to proximity to power wiring and equipment. Ensure properly grounded shielded cables are used on all signal wiring. If the pump is running with a 4.0 mA signal, check wiring and test 4-20mA signal at the pump. Also check 4-20 mA scaling to ensure a 4.0 mA signal results in 0 flow output.

  • Can I use the suction tubing on the discharge side of the pump? What is the maximum pressure capability of the suction tubing?

    The clear PVC suction tubing and opaque polyethylene (PE) discharge tubing included with some pump models are provided to aid in pump installation. The clear PVC tubing is rated for 40 PSI. It can be used on discharge as long as pressure is lower than 40 PSI.

  • What is accuracy of my pump?

    The accuracy of the A4/A4S is +/-5% full-scale accuracy. When the tube has been calibrated the A4/A4S are +/-2% rate accuracy. The motor accuracy is +/-0.5% rated accuracy of the indicated RPM. These accuracy claims are only for water at 72°F with a 5-foot suction lift at atmospheric conditions of sea level.

  • How do I calculate pump output per 1 revolution?

    Default Value is pumping Water. If pumping other than water, make sure feed rate value is calibrated and corrected feed rate value is used. Divide max feed rate value (use ml/mn) divide by max rpm of pump = output per 1 revolution.

  • How do I convert RPM into Motor Speed?

    Determine Max RPM of pump. Select indicated RPM value then divide by Max RPM of pump = New Factor. Use New Factor multiply x 100 = Motor Speed.

  • How do I determine if a pump tube is compatible with the roller assembly installed in my pump?

    Rollers have tube part numbers embossed on the front face. Inspect roller and tube part number to ensure compatibility. Additional information on tube and roller compatibility is available in the Instruction Manuals under Replacement Parts. 

  • Can I use the discharge tubing on the suction side of the pump? What is the maximum pressure capability of the discharge tubing?

    Yes. The clear PVC suction tubing and opaque polyethylene (PE) discharge tubing included with some pump models are provided to aid in pump installation. The opaque PE discharge tubing is rated for 150 PSI. It can be used as suction tubing.

  • Can I use any size suction and discharge tubing? or any brand I want?

    Yes. However, size and material of suction and discharge tubing should be consistent and appropriate for the chemical, flow, and pressure of the system.

Please click here to see help center disclaimers.

  • Ask me a question!

Processing... ...

Stay in the know

Request a quote

Please fill out the form to request a quote.
A sales rep will reach out to you.

To select or deselect multiple products–desktop users hold [ctrl] on Windows or [cmd] on Mac and click products.

Select Products

Pumps
Flow Meters
Skid Systems
Analyzers

Please review your selections before continuing.

Product Details
Select your industry:
How did you hear about us?

We'd like to hear from you...