Common Issues
Air is entering the pump. Check suction lines to make sure all connections are tight. Check the level of the chemical tank. Remove obstructions and clean strainers.
Pump is not accurate. Check and clean the ball checks. Clean the strainer and check for obstructions in suction lines, discharge lines, and injectors. Check discharge and ensure some back-pressure is present.
Solution is leaking from the top or bottom fittings/connectors. Check to ensure o-rings are present and seated properly. Replace O-rings, as necessary. Check tubing connections and tighten them as necessary. Check to make sure all checks are installed properly.
Electricals
The C-1500N will not power up. Check power source or try a different power source. Check to ensure the power cable is properly wired. Check that motor wires are connected properly.
FAQs
Frequently Asked Questions
C-1500N Troubleshooting
- My pump won’t prime out of the box. How do I fix this?
Sometimes it is necessary to lubricate the pump head fittings with water and loosen the ceramic ball checks inside cartridge valve.