Compatible Fluid Types
Clean Water, process water, sea water, Swimming pool water, well water, debris-free effluent wastewater.
Materials of Construction
Molded Inline Tee Fitting: Polypropylene
Saddle Type Fitting: PVDF or PVC
Other Inline Tee: PVC
Sensor: PVDF
Paddlewheel / Axle: PVDF
O-rings: Viton (optional EP)
Enclosure: NEMA 4X (IP56) ABS.
Flow Rates
- Flow Range : .4 – 8,000 GPM (1 – 27,000 LPM)
- Molded Inline : .4 – 200 GPM (1 – 700 LPM)
- Saddle: 15 – 8000 GPM (70 – 27,000 LPM
- PVC Tee: 6 – 600 GPM (25 – 250 LPM)
Units of measure:
US Gallons per Minute (GPM)
US Gallons per Hour (GPH)
US Gallons per Day (GPD)
US Ounces per Minute (OZM)
Cubic Feet per Minute (CFM)
Acre Feet per Day (AFD)
Liters per Minute (LPM)
Liters per Hour (LPH)
Liters per Day (LPD)
Cubic Meters per Hour (M3H)
Imperial Gallons per Minute (IGM)
Imperial Gallons per Hour (IGH)
Dimensions
Weight: Approximately 1.5 lb. (.68kg)
Flow Ranges
Temperature and Pressure Ratings
Operating Ambient Temp: 14 °F to 110 °F (-10 °C to 43 °C)
Maximum Fluid Temperature:
200 °F (93.3 °C) @ 0 PSI (Polypropylene Tees and PVDF saddles)
140 °F (60 °C) @ 0 PSI (all PVC saddles and Tees)
See pressure/temperature chart for details.
Note: Temperature rating for F-1000 only. Actual pipe ratings may vary.
Max working pressure: 300 PSI (20.7 bar) @ 70 °F (21 °C) (see chart)
Maximum Pressure Drop: 8 PSI
Electrical and Controls
Electrical Power Requirements: Two (2) AAA Batteries (included) – Typical battery life is 1 year.
Input and configuration: The F-1000 Flowmeter comes factory configured. There is no programming required. The unit features .35” high LCD display. Totalizer models come with a reset button. Flow/Totalizer models come with a Mode/Reset button.
There is no input or output wiring on the F-1000.
Accuracy
F-1000 accuracy is +/- 2 of full scale. (Must be installed according to installation instructions for best accuracy.)
Repeatability: +/- 1% of full scale reading.
Agency Listings
NEMA 4X, RoHS
FAQs
Frequently Asked Questions
F-1000 Specifications
- What is the maximum fluid debris size that can be used with the F-1000?
0.020" diameter
Is the F-1000 NSF listed?The F-1000 is not NSF listed.
What other display units are available?The F-1000 Digital paddle wheel meter is available in many different display units; GPM, GPH, GPD, OZM, CFM, AFD, LPM, LPH, LPD, M3H, IGM IGH.