Compatible Fluid Types
Clean Water, process water, sea water, swimming pool water, well water, debris-free effluent wastewater. Maximum debris size: 0.020” dia.
Materials of Construction
Molded Inline Tee Fitting: Polypropylene
Saddle Type Fitting: PVDF or PVC
Other Inline Tee: PVC
Sensor: PVDF
Paddlewheel / Axle: PVDF
O-rings: Viton (optional EP)
Enclosure: NEMA 4X (IP56) ABS.
Flow Rates
- Flow Range : .4 – 8,000 GPM (1 – 27,000 LPM)
- Molded Inline : .4 – 200 GPM (1 – 700 LPM)
- Saddle: 15 – 8000 GPM (70 – 27,000 LPM
- PVC Tee: 6 – 600 GPM (25 – 250 LPM)
Units of measure:
US Gallons per Minute (GPM)
US Gallons per Hour (GPH)
US Gallons per Day (GPD)
US Ounces per Minute (OZM)
Cubic Feet per Minute (CFM)
Acre Feet per Day (AFD)
Liters per Minute (LPM)
Liters per Hour (LPH)
Liters per Day (LPD)
Cubic Meters per Hour (M3H)
Imperial Gallons per Minute (IGM)
Imperial Gallons per Hour (IGH)
Dimensions
Weight: Approximately 2 lb. (.91kg)
Temperature and Pressure Ratings
Operating Ambient Temp: 14 °F to 110 °F (-10 °C to 43 °C)
Maximum Fluid Temperature:
200 °F (93.3 °C) @ 0 PSI (Polypropylene Tees and PVDF saddles)
140 °F (60 °C) @ 0 PSI (all PVC saddles and Tees)
See pressure/temperature chart for details.
Note: Temperature rating for F-2000 only. Actual pipe ratings may vary.
Max working pressure: 300 PSI (20.7 bar) @ 70 °F (21 °C) (see chart)
Maximum Pressure Drop: 8 PSI
Electrical and Controls
Electrical Power Requirements / Options:
All units: 15 VDC Nominal required.
B = RT model only. Four (4) AA Batteries (included) – Typical battery life is 1 year.
1 = US. Transformer 115VAC, 60 Hz (15VDC to unit), NEMA 5/15 plug.
2 = Europe Transformer 230VAC, 50 Hz (15VDC to unit), CEE 7/VII plug.
3 = US Transformer 230VAC, 60 Hz (15VDC to unit), NEMA 5/15 plug.
X = customer-supplied power wiring.
Input and configuration: The F-2000 Flowmeter comes factory configured for the pipe fitting and flow units ordered. It can be programmed in the field if the user desires alternate units, or alternate fitting/pipe size.
The F-2000 panel mount option will include 25 feet of signal cable between the sensor and controller. (Alternate cable lengths are available.)
Output options:
F-2000 RT Model: No output.
F-2000 AO Model: 4-20ma or 0-10VDC. Added control board – Linear, Non-isolated, powered loop. (250 ohm max for 4-20 ma) (500 Ohms minimum for 0-10 VDC)
F-2000 PC Model: Added control board – Relay SPDT, NO/NC Maximum switching load 8 amps @ 115 VAC, 220 VAC, 230 VAC; 7 amps @ 30 VDC (resistive load); Max voltage 250VAC, 125 VDC.
F-2000 AP Model: Includes both AO and PC control boards.
Accuracy
F-2000 accuracy is +/- 1 of full scale. (Must be installed according to installation instructions for best accuracy.)
Repeatability: +/- 1% of full scale reading.
Agency Listings
NEMA 4X, RoHS
FAQs
Frequently Asked Questions
F-2000 Specifications
- What are available pipe sizes?
3/8" up to 12"
Can my F-2000 AO be battery powered?No, The AO,PC and AP options require additional power, and are transfomer operated.
What other display units are available?The F-2000 Digital paddle wheel meter is available in many different display units; GPM, GPH, GPD, OZM, CFM, AFD, LPM, LPH, LPD, M3H, IGM IGH.
Is the F-2000 NSF listed?The F-2000 is not NSF listed.
What is the maximum fluid debris size that can be used with the F-2000?0.020" diameter