Compatible Fluid Types
Clean process solution with no particulates. Maximum debris size: 0.020” dia.
Materials of Construction
Molded Body: PVDF
Paddlewheel / Axle: PVDF
O-rings: Viton (optional EP)
Connector Material:
- .5” ID Hose Barb, .5” Male NPT, .5” Female NPT, PVC
- .25” OD Tubing Connection, Polypropylene
- .125” Female NPT, PVC
- .375” OD Tubing Connection, PVDF
- .250” Female NPT, PVC
Enclosure: NEMA 4X (IP56) ABS.
Measurable Flow Rates (6 model options)
- Model 10: 1-10 oz/min, 30-300 ml/min, .48 – 4.8 gph, 11.4 – 114 gpd (.031 flow orifice size)
- Model 20: 3.5- 35 oz/min, 100-1000 ml/min, 1.6 – 15.6 gph, 38 -380 gpd (.062 flow orifice)
- Model 30: 7 – 70 oz/min, 200-2000 ml/min, 3.2 – 31.7 gph, 76 – 760 gpd. (.093 flow orifice)
- Model 40: 10 – 100 oz/min, 300-3000 ml/min, 4.8 – 47.5 gph, 114 – 1140 gpd. (.125 flow orifice)
- Model 50: 17-170 oz/min, 500-5000 ml/min, 7.9 – 79 gph, 190 – 1900 gpd. (.156 flow orifice)
- Model 60: 24-240 oz/min, 700-7000 ml/min, 11.1 – 111 gph, 266 – 2660 gpd. (.187 flow orifice)
Dimensions
Weight: Approximately .5 lb.
Temperature and Pressure Ratings
Operating Ambient Temp: 14 °F to 110 °F (-10 °C to 43 °C)
Maximum Fluid Temperature:
200 °F (93.3 °C) @ 0 PSI (PVDF)
140 °F (60 °C) @ 0 PSI (PVC, PP)
See pressure/temperature chart for details.
Max working pressure: 150 PSI (10 bar) @ 70 °F (21 °C) (see chart)
Maximum Pressure Drop:
up to 10 PSI (on 30, 40, 50, 60 flow range models)
up to 20 PSI (on 20 flow range model)
up to 50 PSI (on 10 flow range model)
Electrical and Controls
Electrical Power Requirements / Options:
All units: 9-28 VDC Nominal required.
Sensor Type: Infra-red light beam
Sensor output: 5V CD digital square wave (3 wire)
Sensor cable: 3-wire shielded cable, 6ft
Enclosure: NEMA 4X (IP56)
Accuracy
MICRO-FLO accuracy is +/- 6% of full scale. (Must be installed according to installation instructions for best accuracy.)
Repeatability: +/- 1% of full scale reading.
Agency Listings
NEMA 4X, RoHS