Performance for C2
C2*2*5*** Pump with .040” (1.02mm) stroke with Micro-Feed Diaphragm
Maximum Flow/Pressure:
- 0.23 gph at 150 PSI
- 0.95 gph at 90 PSI
- 1.4 gph at 40 PSI
- 2.3 gph at 0 PSI
C2*2*6*** Pump with .060” (1.52mm) stroke with Micro-Feed Diaphragm
Maximum Flow/Pressure:
- 2.0 gph at 150 PSI
- 2.7 gph at 90 PSI
- 3.4 gph at 40 PSI
- 4.0 gph at 0 PSI
C2*2*3*** Pump with .040” (1.02mm) stroke with Small Diaphragm
Maximum Flow/Pressure:
- 5.0 gph at 175 PSI
- 5.5 gph at 120 PSI
- 6.1 gph at 60 PSI
- 6.7 gph at 0 PSI
C2*2*1*** Pump with .060” (1.52mm) stroke with Small Diaphragm
Maximum Flow/Pressure:
- 7.5 gph at 175 PSI
- 8.3 gph at 120 PSI
- 9.25 gph at 60 PSI
- 10.0 gph at 0 PSI
C2*2*2*** Pump with .060” (1.52mm) stroke with Large Diaphragm
Maximum Flow/Pressure:
- 12.5 gph at 175 PSI
- 13.75 gph at 120 PSI
- 15.1 gph at 60 PSI
- 16.5 gph at 0 PSI
Connections
Fitting connections for C2 pump:
- “A” = 1/2” Hose Barb Inlet, 1/2” Male NPT Outlet, with1/2” Male NPT Injector
- “B” = 1/2” Hose Barb Inlet, ½” Female NPT Outlet, with 1/2” Male NPT Injector
- “C” = 1/2” Hose Barb Inlet and Outlet, with 1/2” Hose Barb Injector
- “D” = 3/8” OD Tube Compression Inlet, Outlet, and Injector
- “E” = 1/2” Male NPT Inlet and Outlet, with 1/2” Male NPT Injector
- “F” = 1/2” Female NPT Inlet and Outlet, with 1/2” Male NPT Injector
- Maximum Viscosity: 1,000 Centipoise
- Maximum Suction Lift: 15 ft water at sea level (14.7 atm psi)
Electrical and Controls
Electrical Power Requirement: 100 to 240VAC, 50/60Hz
Motor: Brushed DC, 100:1 Turndown, Continuous Duty (100% motor speed = 166 rpm/spm)
Power cord options available (6 feet length):
- 115VAC 50/60HZ, NEMA 5/15 plug (U.S.)
- 220VAC 50/60HZ ,CEE 7/V11 plug (EU)
- 230VAC 50/60HZ, NEMA 6/15 (U.S.)
- 240VAC 50/60HZ, AS 3112 plug (Australia / New Zealand)
- 230VAC 50/60HZ, BS 1363/A plug (UK)
Inputs:
- 4-20 mA – fully configurable (V model)
- Frequency / Pulse input – fully configurable (V model)
- Stop/Start Dry Contact Closure (or Wet Contact) (Normally Open)
- FVS (Flow Verification System) (Flow sensor provided by others)
Outputs:
- Motor Active output (Open collector)
- Alarm Output – Triggers with DFD or FVS
Materials of Construction
Non-wetted Components:
- Enclosure: 413 Aluminum (Polyester powder coated) – NEMA 4X (IP 66)
- Cover Screws: 300 Series stainless steel
- Pump Head Cover: 316 Stainless Steel
- Motor Shaft: Chrome-plated steel
- DFD System Sensor pins: Hastelloy C-276
- Power Cord: 3 conductor, SJTW-A water-resistant
- Mounting Brackets and Hardware: 316 Stainless steel
Wetted Components:
- Pump Head: PVDF
- Adapter Connections: PVDF
- Valve Cartridges: PVDF
- Valve Balls: Ceramic
- Elastomers: TFE/P
- Static Seals: TFE/P (optional EP)
- Diaphragm: DiaFlex® (optional Flex-A-Prene)
Diaphragm Options
DiaFlex® Diaphragm – This material consists of a natural PVDF flexible single-layer design compatible with most acids and bases. DiaFlex® is not compatible with sodium hydroxide or ammonia.
Flex-A-Prene® Diaphragm – An excellent material for most water treatment applications. Chemically resistant to 50% sodium hydroxide and many others.
Dimensions and Weights
Maximum Overall Dimensions: 13.1”W x 7.9”H x 11.5”D (33.2W x 20.1H x 29.2D cm)
Product Weight: 24 lb (10.9 Kg)
Product Shipping Weight: 31 Lb. (14 Kg) (approximate)
Agency Listings
CE
cETLus
RoHS Compliant
NEMA 4X