Blue-White - Chemical metering and fluid measurement solutions; chemical metering pumps, peristaltic pumps, diaphragm pumps, multi-diaphragm pumps, flow meters, flowmeters, variable area flow meters, paddlewheel flow meters, ultrasonic flow meters, engineered skid systems, single skid system, duplex skid system, triplex skid system, water analyzers...
Oswald

Industrial

C2

Set-Up and Controls 

Powering On the C2 

The C2 is powered on when plugged into the power source.  The pump will take approximately 10 seconds to power on, boot, and be ready for service.  

The C2 pump Main Screen will appear when powered on, showing pump status, operating mode, and any alarms or errors. 

Display and Layout 

The C2V has a 5-button LCD display that is easy to read and simple to use.  

All pump settings can be configured by pressing the Mode button, and using the other buttons to navigate.  See Control Panel – Button Operation display below. 

image 13

(For the C2F model, the display will be slightly different and will not include a Mode button for programming.) 

The C2V Pump has the following Control Buttons: 

  • image 14 MODE  – Press to scroll through run Modes. Press and Hold for Set-Up.  
  • image 15 PRIME  – Press to prime the pump at full speed for 60 seconds. 
  • image 16 START  – Press to Start pump. (Press and Hold to program “F” model) 
  • image 17 STOP –      Press to Stop pump.  
  • image 18 UP ARROW  – When in Configure – used to toggle through menu items.  When in Manual Speed Adjust mode – used to increase the speed of the pump.  
  • image 19 DOWN ARROW – When in Configure – used to toggle through menu items.  When in Manual Speed Adjust mode – used to decrease the speed of the pump.  

Configuration for the C2F pump 

The C2F pump has limited features with no external speed control. The C2F has Manual speed control only, Remote Start/Stop feature, FVS option, and DFD (Leak detection).  

Activation of the Remote Start/Stop and FVS features: 

  1. While pump is stopped, Press and Hold Start/Stop button until “Remote” icon begins flashing. 
  2. Use up and down arrows to select “Yes” or “No”. 
  3. Press the Start/Stop button to save setting.  
  4. The “FVS” will appear, followed by “00 sec”   
  5. You can now activate the FVS by using the up and down arrows to set a delay time. (If you are not using FVS, do not enter a delay time. Press and Hold Start/Stop button to exit programming.  
  6. If you are activating the FVS and have set a delay time, you can now press and Hold the Start/Stop button to save and exit.  

Note: C2 pump has a “time out” feature when programming. If you do not press a button within 20 seconds, the pump will exit programming automatically.) 

Mode and Configuration for the C2V pump 

image 20

All C2V pump settings and programming are done via the Mode Navigation. Press and hold Mode button to Configure the pump and Program inputs and outputs:  

Configuration 

Use the Configuration to: 

  1. Program Remote Start/Stop 
  2. Set DFD Sensitivity 
  3. Activate FVS (Flow Verification) 
  4. Configure 4-20 mA signal output (optional output on older models) 

Configuration Details and Set-up  

When in Configuration (Mode 0) Set-up, use the Mode button and Up and Down arrows to scroll through the different configuration options.    

  1. Remote Start/Stop. Active by choosing “Yes”.  Close = Start, Open = Stop.  
  2. DFD Sensitivity is set to 78% default. This will trigger on most chemicals, but will not trigger with tap water and condensation. Adjust sensitivity to 100% to sense water and more diluted chemicals.  
  3. Choose to activate FVS by setting a delay time. If a FVS sensor is not used, keep this setting at 00 sec. FVS sensor is provided separately. Contact factory for sensor options.    
  4. 4-20mA output signal is fully configurable.  Default is 4 mA = 0% motor speed, 20 mA = 100% motor speed. (This feature is optional on older models. No longer available on new pumps.) 

Operating Modes (Programming) 

The C2V Pump includes a variety of Operating Modes. Use the Mode button to select the Operating Mode of your choice:   

  1. Mode 1. Manual Speed Adjust.  Choose pump speed at the pump by using up or down buttons. 
  2. Mode 2. 4-20 mA. Pump will run at a speed proportional to the 4-20ma signal. 
  3. Mode 3 Frequency. Pump will run at a speed proportional to the Frequency signal (0-1000Hz.) 
  4. Mode 4. Pulse Batch. Pump will run for a set time and speed when the pump receives a programmed number of pulse signals.  

To program/configure a Mode, hold the Mode button for 5 seconds while in the Mode. This will activate programming for that Mode. Follow the steps for programming each Mode. Refer to C2 Manual for more details. 

Pump Output Setup 

The C2 Pump includes output signals for monitoring pump status and alarms.  Use the Output Setup to program the following:  

  1. 4- 20 mA Signal Output.  (no longer available on new C2 pumps.) 
  2. Motor On/Off Output.  (No longer available on new C2 pumps.) 
  3. Motor speed. Open Collector output. (V model only) 
  4. Output Alarm.  One Relay output will trigger with DFD or FVS alarm. 
     

Power Fail 

The C2 Pump will resume running operation when power is returned after power failure. 

Please click here to see help center disclaimers.

  • Ask me a question!

Processing... ...

Stay in the know

Request a quote

Please fill out the form to request a quote.
A sales rep will reach out to you.

To select or deselect multiple products–desktop users hold [ctrl] on Windows or [cmd] on Mac and click products.

Select Products

Pumps
Flow Meters
Skid Systems
Analyzers

Please review your selections before continuing.

Product Details
Select your industry:
How did you hear about us?

We'd like to hear from you...

ImageCatalog NumberDescriptionPriceBuy