Performance
Maximum Fluid Temperature: 130 °F (54 °C)
Maximum Viscosity: 5,000 Centipoise
Maximum Suction Lift: 30 ft at sea level (14.7 atm psi)
Electrical and Controls
Electrical Power Requirement:
115VAC/60Hz, 1ph (.51 amp max)
230VAC/60Hz, 1ph (.56 amp max)
220VAC/50Hz, 1ph (.66 amp max)
240VAC/50Hz, 1ph (.59 amp max)
Motor: DC, Gearmotor, 14 rpm, 30 rpm, 45 rpm, or 60 rpm.
Power cord options available (6 feet length):
- 115VAC 50/60HZ, NEMA 5/15 plug (U.S.) – (choose when specifying pump model)
- 220VAC 50/60HZ , CEE 7/V11 plug (EU) – (choose when specifying pump model)
Signal Connections: Color-coded wires, liquid-tight junction box.
Inputs:
- 4-20 mA – fully configurable
- 0-10 VDC
- Pulse Frequency (Sine wave or Hall Effect)
- FVS (Flow Verification System) (Flow sensor provided by others)
Outputs:
- Alarm Output – Normally Open (can be changed to Normally Closed by changing jumper on internal circuit board). Activated by TFD (leak detection) and FVS (flow verification – flow sensor ordered separately)
- Motor On Status – open collector output
Materials of Construction
Pump Head: Valox® (PBT)
Pump Head Cover: Acrylic, with permanently sealed motor shaft support bronze sleeve bearing.
Cover Screws: Stainless steel, polypropylene cap.
Roller assembly: Rotor – Valox, Rollers – Nylon, Roller bearings – Bronze.
Motor Shaft: Chrome-Plated Steel
TFD Sensor: Hastelloy C-276 pin contacts
Power Cord: 3 Conductor, SJTW-A water-resistant
Enclosure: NEMA 3R (IP23) Valox
Tube Assembly Options
Flex-A-Prene® tubing – An excellent material for most water treatment applications. Chemically resistant to 25% Sodium Hypochlorite, 30% Sulfuric Acid, 30% Fluosilicic Acid, Ferric Chloride, Alum, and many others.
Flex-A-Chem® tubing – This material consists of an outer Norprene jacket with an inner liner that is virtually unaffected by acids, bases, salts, ketones, and alcohols.
Flex-A-Thane® tubing – This polyurethane material can be used with a variety of chemicals, including Oil and Water based Polymers, fuels and lubricants, and many others.
Dimensions and Weights
Maximum Overall Dimensions: 9.5” W x 6.0” H x 9.125” D (24.1 W x 15.2 H x 23.2 D cm)
Product Weight: 8.5 Lb. (3.8 Kg)
Approximate Shipping Weight: 12 lb. (5.4kg)
Agency Listings
cETLus
RoHS Compliant
FAQs
Frequently Asked Questions
A-100NV Specifications
- Does the A-100NV have 4-20 MA capability?
The A-100NV has 4-20ma input for speed control.
What is suction lift?Suction lift is the maximum vertical distance that a pump can draw liquid from a source below the pump centerline. This is typically measured in feet or meters of water.
Suction lift is limited by the atmospheric pressure. Atmospheric pressure is the force exerted by the weight of the air above the Earth's surface. As the liquid level in the suction line drops, the atmospheric pressure decreases. This decrease in atmospheric pressure reduces the suction force that the pump can generate.
If the liquid level in the suction line drops too low, the atmospheric pressure will be insufficient to overcome the vapor pressure of the liquid. Vapor pressure is the pressure exerted by the vapor of a liquid in equilibrium with its liquid state. When the vapor pressure of the liquid equals the atmospheric pressure, the liquid will begin to vaporize.