Accessories
Strainer – To improve priming and minimize debris entering the pump, it is recommended that a strainer be used with the system. A strainer is provided with the pump. Additional foot valve and strainer options are available.
Injector – An injector is provided with the pump for injecting into piping and vessels. It can also be used to prevent siphoning when pumping downhill. A standard injector is provided with the pump. Additional injector options are available.
Tubing (Suction and Discharge) – A 5’ length of clear PVC suction tubing and PE discharge tubing are provided with the pump. Additional tubing options and lengths are available.
Wall Mount Bracket (Shelf) – Blue-White offers a sturdy polyethylene Wall Mount Bracket for easy mounting on a shelf.
Tanks – Blue-White has a variety of tank systems and cylindrical tanks available.
Additional piping accessories– Blue-White can provide additional items for your system including pressure gauges, pressure switches, pressure relief valves, calibration columns, back-pressure valves, pulsation dampeners, and strainers.
Complete Skids – Blue-White manufactures complete skids systems for ease in installation and set-up. Visit our skid page for options.
Spare Parts
The A-100NV Pump complete spare parts list is located in the Instruction Manual. Recommended spare parts are list below:
ITEM NO. | PART NUMBER | DESCRIPTION | QTY |
1 | 90011-014 | Spacer, Back | 1 |
2 | 71000-350 | Roller Assembly (Rotor) for use with A1-1T, A1-2T, A1-3T, and A1-7T tubes | 1 |
2 | 71000-159 | Roller Assembly (Rotor) for use with A1-4T, and A1-6T tubes | 1 |
2 | 71000-255 | Roller Assembly (Rotor) for use with A1-8T tubes | 1 |
3 | A1-1T | Tube Assembly, ¼” OD, Flex-A-Thane® | 1 |
3 | A1-3T | Tube Assembly, 7/16” OD, Flex-A-Thane® | 1 |
3 | A1-4T | Tube Assembly, ¼” OD, Flex-A-Prene® | 1 |
3 | A1-6T | Tube Assembly, 3/8 OD, Flex-A-Prene® | 1 |
3 | A1-7T | Tube Assembly, 7/16” OD, Flex-A-Prene® | 1 |
3 | A1-8T | Tube Assembly, 7/16” OD, Flex-A-Chem® | 1 |
4 | A1-SXX-C | Pump Head Cover, Acrylic | 1 |
5 | 90011-160 | Thumb Screw with 9/64” key drive (maximum torque 6-8 in-lbs) | 3 |
6 | C-330-6 | Tube Nut, Compression, for 3/8” Tubing | 2 |
7 | 90002-191 | Touchpad Cover, Polycarbonate | 1 |
C-342-6 | Strainer, Inlet Tube, Polypropyene | 1 | |
C-346 | Weight, Ceramic | 1 | |
A-014N-6A | Injector Valve Assy, ½” & ¼”, for use with ¼” x 3/8” tubing. | 1 | |
C-334-6 | Suction Tubing, Clear PVC, 5 ft | 1 | |
C-335-6 | Discharge Tubing, Polyethylene, 5 ft | 1 | |
FAQs
Frequently Asked Questions
A-100NV Accessories and Spare Parts
- Will one roller assembly work with all pump tube choices?
No, the A1-4T & A1-6T use roller 71000-159, A1-7T, A1-1T, A1-2T, A1-3T use roller part number 71000-350.
Can I switch to a different tube after I have the pump?Yes, you can. But the tube assembly used must be compatible with the roller assembly used. Tube numbers 1T, 2T, 3T, and 7T must be used with roller assembly number 71000-350.
Tube numbers 4T and 6T must be used with roller assembly number 71000-159.
Tube numbers 5T and 8T must be used with roller assembly number 71000-255.
How much do replacement tubes cost?Replacement tubes are costs are minimal. Please contact a local distributor for spare parts pricing.
What spares parts are recommended?Pump tube assembly.