Performance for M2
Model Tube | Tubing Material | Feed Rate | Max Speed | Max Pressure | Max Temp | ||
GPH | LPH | mL/Min | RPM | PSI(bar) | °F(°C) | ||
A2-*ND-T | Flex-A-Prene | .01 – 1.7 | .03 – 6.5 | .54 – 108 | 125 | 125 (8.6) | 185 (85) |
A2-*NEE-T | Flex-A-Prene | .022- 4.44 | .084 – 16.8 | 1.4 – 280 | 125 | 110 (7.6) | 185 (85) |
A2-*NGG-T | Flex-A-Prene | .086 – 17.2 | .325 – 65.1 | .5.4 – 1085 | 125 | 110 (7.6) | 185 (85) |
A2-*TH-T | Flex-A-Chem | .07 – 14.4 | .27 – 54.0 | 4.5 – 900 | 125 | 50 (3.4) | 130 (54) |
A2-*GE-T | Flex-A-Thane | .02 – 4.0 | .08 – 15.2 | 1 – 253 | 125 | 65 (4.5) | 130 (54) |
A2-*GG-T | Flex-A-Thane | .05 – 9.3 | .17 – 35.2 | 3 – 587 | 125 | 65 (4.5) | 130 (54) |
A2-*G2G-T | Flex-A-Thane | .07 – 14.98 | .03 – 56.7 | 4.7 – 945 | 125 | 65 (4.5) | 130 (54) |
A2-*GH-T | Flex-A-Thane | .106 -21.23 | .04 – 80.4 | 6.7 – 1340 | 125 | 65 (4.5) | 130 (54) |
Fitting connections for M2 pump = *
“S” = 3/8” OD x 1/4” ID Tube Compression Fitting
“M” = 1/2” Male NPT
“B” = 1/2” Hose Barb
“C” = ½” – ¾” Tri-Clamp
“Q” = Quick Disconnect
“MB” = 1/2 Male BSPT
Maximum Viscosity: 5,000 Centipoise
Maximum Suction Lift: 30 ft at sea level (14.7 atm psi)
Electrical and Controls
Electrical Power Requirement: 100 to 240VAC, 50/60Hz
Motor: Brushed DC, 200:1 Turndown, Continuous Duty
Power cord options available (6 feet length):
- 115VAC 50/60HZ, NEMA 5/15 plug (U.S.)
- 220VAC 50/60HZ ,CEE 7/V11 plug (EU)
- 230VAC 50/60HZ, NEMA 6/15 (U.S.)
- 240VAC 50/60HZ, AS 3112 plug (Australia / New Zealand)
- 230VAC 50/60HZ, BS 1363/A plug (UK)
Inputs:
- 4-20 mA – fully configurable
- Frequency / Pulse input – fully configurable
- Stop/Start Dry Contact Closure (Configurable for N.O. or N.C.)
- FVS (Flow Verification System) (Flow sensor provided by others)
Outputs:
- 4-20 mA output – fully configurable
- Motor Status (Open collector)
- Motor Output (Contact closure)
- One (1) Alarm Output – TFD and FVS
Materials of Construction
Pump Head: Valox® (PBT)
Pump Head Cover: Polycarbonate, with permanently sealed motor shaft support bronze sleeve bearing.
Cover Screws: Stainless steel, polypropylene cap.
Roller assembly: Rotor – Valox, Rollers – Nylon.
Motor Shaft: Chrome-Plated Steel
TFD Sensor: Hastelloy C
Power Cord: 3 Conductor, SJTW-A water-resistant
Mounting Brackets: 316 Stainless Steel (standard and extended)
Enclosure: NEMA 4X (IP66) Powder Coated Aluminum
Tube Fittings: PVDF (part of tube assembly)
Tube Assembly Options
Flex-A-Prene® tubing – An excellent material for most water treatment applications. Chemically resistant to 25% Sodium Hypochlorite, 50% Sodium Hydroxide, 30% Sulfuric Acid, 30% Fluosilicic Acid, Ferric Chloride, Alum and many others.
Flex-A-Chem® tubing – This material consists of an outer Norprene jacket with an inner liner that is virtually unaffected by acids, bases, salts, ketones, and alcohols.
Flex-A-Thane® tubing – This polyurethane material can be used with a variety of chemicals, including Oil and Water based Polymers, fuels and lubricants, and many others.
Flex-A-Prene®, Flex-A-Chem®, and Flex-A-Thane® tubing comply with FDA 21 CFR, 117.2600 criteria for food processing.
Dimensions and Weights
Maximum Overall Dimensions: 7.5” W x 10.25” H x 14” D (19 W x 26 H x 35.6 cm)
Product Weight: 28.4 Lb. (12.9 Kg)
Approximate Shipping Dimensions: 16” W x 17” H x 22” D ( 40.5 W x 43 H x 56 D cm)
Approximate Shipping Weight: 35 lb. (16.0kg)
Agency Listings
CE
cETLus
RoHS Compliant
NSF 61 Listed
FAQs
Frequently Asked Questions
M2 Specifications
- What is NSF 61?
NSF 61 is a set of regulations and standards developed by NSF International that relates to the safety and performance of drinking water system components. It focuses on ensuring that products and materials that come into contact with drinking water are safe and do not pose a risk of contaminating the water supply.
What is viscosity?Viscosity is a measure of the resistance of a fluid to flow. It is the internal friction of a fluid that causes adjacent layers of fluid to resist moving past each other. The higher the viscosity, the more resistance there is to flow.