Performance for M4S
Model Tube | Tubing Material | Feed Rate | Max Speed | Max Pressure | Max Temp | ||
GPH | LPH | mL/Min | RPM | PSI(bar) | °F(°C) | ||
A4-*NH-T | Flex-A-Prene | .0028 – 28.5 | .0108 – 108 | 0.18 – 1800 | 125 | 125 (8.6) | 185 (85) |
A4-*NHL-T | Flex-A-Prene | .0028 – 28.5 | .0108 – 108 | 0.18 – 1800 | 125 | 65 (4.5) | 185 (85) |
A4-*NK-T | Flex-A-Prene | .0050 – 50.7 | .0192 – 192 | .32 – 3200 | 125 | 80 (5.5) | 185 (85) |
A4-*NHH-T | Flex-A-Prene | .0054 – 54.0 | .0204 – 204 | .34 – 3400 | 125 | 100 (6.9) | 185 (85) |
A4-*NHHL-T | Flex-A-Prene | .0054 – 54.0 | .0204 – 204 | .34 – 3400 | 125 | 65 (4.5) | 185 (85) |
A4-*NL-T | Flex-A-Prene | .010 – 100.0 | .0378- 378 | .63 – 6300 | 125 | 50 (3.4) | 185 (85) |
A4-*NP-T | Flex-A-Prene | .015 – 158.5 | .060 – 600 | 1.0 – 10000 | 125 | 30 (2.1) | 185 (85) |
A4-*TH-T | Flex-A-Chem | .0025 – 25.4 | .0096 – 96 | 0.16- 1600 | 125 | 30 (2.1) | 130 (54) |
A4-*TK-T | Flex-A-Chem | .0054 – 54.0 | .0020 – 204 | .34 – 3400 | 125 | 30 (2.1) | 130 (54) |
A4-*TKK-T | Flex-A-Chem | .0126 – 126 | .0477 – 477 | .08 – 8000 | 125 | 30 (2.1) | 130 (54) |
A4-*GH-T | Flex-A-Thane | .0039 – 39.6 | .0015 – 150 | .25 – 2500 | 125 | 65 (4.5) | 130 (54) |
A4-*GHH-T | Flex-A-Thane | .0071 – 71.0 | .0269 – 269 | .448 – 4480 | 125 | 65 (4.5) | 130 (54) |
A4-*GK-T | Flex-A-Thane | .0028 – 28.5 | .0021 – 210 | .35 – 3500 | 125 | 65 (4.5) | 130 (54) |
A4-*GKK-T | Flex-A-Thane | .001 – 100.0 | .0378 – 378 | .63 – 6300 | 125 | 65 (4.5) | 130 (54) |
Fitting connections for M4S pump = *
“M” = 1/2” Male NPT
“B” = 1/2” Hose Barb
“C” = ½” – ¾” Tri-Clamp
“Q” = Quick Disconnect
“MB” = 1/2 Male BSPT
Maximum Viscosity: 5,000 Centipoise
Maximum Suction Lift: 30 ft at sea level (14.7 atm psi)
Electrical and Controls
Electrical Power Requirement: 100 to 240VAC, 50/60Hz
Motor: Brushless DC, 10,000:1 Turndown, Continuous Duty
Power cord options available (6 feet length):
- 115VAC 50/60HZ, NEMA 5/15 plug (U.S.) – (choose when specifying pump model)
- 220VAC 50/60HZ ,CEE 7/V11 plug (EU) – (choose when specifying pump model)
- 230VAC 50/60HZ, NEMA 6/15 (U.S.) – (ordered separately)
- 240VAC 50/60HZ, AS 3112 plug (Australia / New Zealand) (ordered separately)
- 230VAC 50/60HZ, BS 1363/A plug (UK) (ordered separately)
Signal Connectors: M12 – 5 pin, IP67 rated connectors
Inputs:
- 4-20 mA – fully configurable
- Frequency / Pulse input – fully configurable
- Stop/Start Dry Contact Closure (Configurable for N.O. or N.C.)
- Auto Prime – Secondary Contact Closure
- FVS (Flow Verification System) (Flow sensor provided by others)
Outputs:
- 4-20 mA output – fully configurable
- Frequency output (Open collector)
- Four (4) Alarm Outputs – Programmable.
Materials of Construction
Pump Head: Valox® (PBT)
Pump Head Cover: Polycarbonate, with permanently sealed motor shaft support bronze sleeve bearing.
Cover Screws: Stainless steel, polypropylene cap.
Roller assembly: Rotor – Valox, Rollers – Nylon.
Motor Shaft: Chrome-Plated Steel
TFD Sensor: Hastelloy C
Power Cord: 3 Conductor, SJTW-A water-resistant
Mounting Brackets: 316 Stainless Steel (standard and extended)
Enclosure: NEMA 4X (IP66) Valox
Tube Fittings: PVDF (part of tube assembly)
Tube Assembly Options
Flex-A-Prene® tubing – An excellent material for most water treatment applications. Chemically resistant to 25% Sodium Hypochlorite, 30% Sulfuric Acid, 30% Fluosilicic Acid, Ferric Chloride, Alum and many others.
Flex-A-Chem® tubing – This material consists of an outer Norprene jacket with an inner liner that is virtually unaffected by acids, bases, salts, ketones, and alcohols.
Flex-A-Thane® tubing – This polyurethane material can be used with a variety of chemicals, including Oil and Water based Polymers, fuels and lubricants, and many others.
Flex-A-Prene®, Flex-A-Chem®, and Flex-A-Thane® tubing comply with FDA 21 CFR, 117.2600 criteria for food processing.
Dimensions and Weights
Maximum Overall Dimensions: 12-1/8”W x 15-1/4”H x 16-1/2”D (30.8W x 38.8H x 41.9D cm)
Product Weight: 45.5 Lb. (20.64 Kg)
Approximate Shipping Weight: 50 lb. (22.68 Kg)
Agency Listings
CE
cETLus
RoHS Compliant
NSF 61
FAQs
Frequently Asked Questions
M4S Specifications
- How accurate is the analog input? e.g. If I send it 0.1 mA, will the pump read 0.1 mA? Could the pump possible run if I send it 4.0mA?
The A3, A4, M3, M4 pumps will read 4-20mA signals to a resolution of .05 mA. The pumps will be able to read signals in increments of 0.1 mA. It is possible the pump may not read the exact value of signal being sent from the control/PLC/SCADA, as there can be electrical noise due to proximity to power wiring and equipment. Ensure properly grounded shielded cables are used on all signal wiring. If the pump is running with a 4.0 mA signal, check wiring and test 4-20mA signal at the pump. Also check 4-20 mA scaling to ensure a 4.0 mA signal results in 0 flow output.
Can I use any size suction and discharge tubing? or any brand I want?Yes. However, size and material of suction and discharge tubing should be consistent and appropriate for the chemical, flow, and pressure of the system.