Blue-White - Chemical metering and fluid measurement solutions; chemical metering pumps, peristaltic pumps, diaphragm pumps, multi-diaphragm pumps, flow meters, flowmeters, variable area flow meters, paddlewheel flow meters, ultrasonic flow meters, engineered skid systems, single skid system, duplex skid system, triplex skid system, water analyzers...
Oswald

Industrial

S6A

Product Specifications

Compatible Fluid Types

Acoustically conductive fluids

Particulate and bubbles with 50,000 ppm or less

Pre-Calibrated Chemical Profiles

  • Water
  • Aqueous Ammonia
  • Ammonium Hydroxide
  • Ferric Chloride 40%
  • Sodium Bisulfite 40%
  • Sodium Hypochlorite 12.5%
  • Sodium Permanganate
  • Hydrofluorosilicic Acid 25%
  • Ammonium Sulfate 10%

Additional approved chemicals (customer digital calibration required.)

  • Alum (Aluminum Sulfate 48%)
  • Ferric Chloride 50%

Non-working chemicals

  • Sodium Hydroxide
  • Peroxide
  • Neat polymers

Materials of Construction

Inline Pipe Fitting/Transducer:

Transducer: PEEK – See chemical resistance

Pipe Fitting: PVDF (optional PVC) – See chemical resistance

Enclosure: NEMA 4X (IP66) Polycarbonate.

Sizes and Flow Rates

Range 1: 10 – 5,000 mL/min (0.158 – 79.2 GPH), Range 2: 100 – 10,000 mL/min (1.58 – 158.5 GPH).

Units of measure: Configurable for US Gallons, Liters, or milliliters. And time units of seconds, minutes, hours, and days.

Dimensions

image 14

Weight: 1.5 lb. (.68kg)

Temperature and Pressure Ratings

Operating Temp. 14 °F to 104 °F (-10 °C to 40 °C)

Max pressure: 200 PSI

image 6

Electrical and Controls

Electrical Power Requirements:  5VDC (5 watts max.)

S6A ships with power supply cord kit which includes:

  • U.S. Transformer, 115VAC 60HZ / 5VDC, NEMA 5/15 plug
  • Europe Transformer, 230VAC 50HZ / 5VDC, CEE 7/V11 plug
  • Australia / New Zealand Transformer, 240VAC 50HZ / 5VDC, AS 3112 plug
  • U.K. Transformer, 230VAC 50Z / 5VDC, BS 1363/A plug

Input and configuration:  All configuration and input programming is done through the Blue-Central software. Blue-Central Software is downloadable from the Blue-White website and is compatible with Windows 7, 8, 10, 11 or Mac (OSX 10.11/10.12/10.13). Connector to the S6A is via USB-C to USB-A cable.(included.)

Outputs:

  • Isolated 4-20 mA output – fully configurable
  • 0-10000 Hz Pulse output – fully configurable

One Solid State Relay, Load capacity: 24V, 100mA max (ext. supplied)

  • Configure to flow rate for high/low/range rate trigger. Programmable release values enable auto release or manual latching operation.
  • Configure to flow total for automatically triggered, timed batch operations for proportional feed applications.

Accuracy

S6A accuracy with pre-configured chemicals is +/- 5 of flow reading.  Accuracy other chemicals that have had a customer chemical calibration are +/- 5% of flow reading (flow reading must be within +/- 50% of calibrated flow.)

image 5
image 4

Agency Listings

CE – complies to the IEC 61000-6-1 and 6-3, IEC 61000-3-2 and 3-3 

FAQs

Frequently Asked Questions

S6A Specifications

  • Are there any chemicals that will not work with S6A?

    Yes. There are chemicals that will not work with the S6A, specifically sodium hydroxide, sulfuric acid, and neat polymers. Chemicals must be acoustically conductive and contain particulate less than 50,000 ppm.

  • What is the maximum viscosity of the S6A?

    Blue-White does not have a strict viscosity limit for the S6A.

  • Is the S6A rated NSF 61?

    No. The S6A flow meter is not rated NSF 61. The MS6 flow meter is rated NSF 61.

  • How do I find out if my chemical will work with the S6A?

     

  • If my chemical has bubbles, can it be used on the S6A?

    The S6A meter can measure chemicals with bubbles and particles provided the bubbles and particles are not so large, or numerous, as to block the ultra-sonic sound beam. For example, the S6A functions very well measuring sodium hypochlorite. The S6A meter takes many measurements per second, so while small bubbles and particles can reduce the number and quality of the measurements, the meter is still able to take enough measurements for an accurate reading. Installing a strainer/filter directly before the S6A can break up large bubbles and filter out particles.  

  • What chemicals can, and can’t be used with the S6A?

    The sensor will work with acoustically conductive fluids with particulate and bubbles 50,000 ppm or less. A list of Pre-Configured (factory-tested) chemicals is available in the product datasheet, and includes: 

    • Water
    • Aqueous Ammonia 10%
    • Ammonium Hydroxide 30%
    • Ferric Chloride 40%
    • Sodium Bisulfite 40%
    • Sodium Hypochlorite 12.5%
    • Sodium Permanganate 40%
    • Hydrofluorosilicic Acid 25%
    • Ammonium Sulfate 10%

    Additional approved (non factory tested) chemicals are:

    • Alum
    • Ferric Chloride

    Chemicals that can’t be used:

    • Sodium Hydroxide
    • Sulfuric Acid
    • Neat polymers
  • Why is the accuracy different for different chemicals?

    Different chemicals have different accuracies in an ultrasonic meter because they have different acoustic properties. Acoustic properties are the physical properties of a material that affect the way sound waves propagate through it. Some of the most important acoustic properties for ultrasonic flowmeters are the speed of sound, the attenuation coefficient, and the density. The speed of sound in a fluid is the distance that a sound wave travels in a unit of time. The speed of sound is affected by the temperature and pressure of the fluid, as well as the composition of the fluid. The attenuation coefficient is a measure of how much sound energy is lost as it travels through a fluid. The attenuation coefficient is affected by the composition of the fluid, as well as the frequency of the sound wave. The density of a fluid is the mass per unit volume. The density of a fluid affects the way sound waves propagate through it.

  • How repeatable are the measurements over time?

    We do not have exact data at this time but Ultrasonic flowmeters are generally very repeatable. The repeatability of an ultrasonic flowmeter is affected by a number of factors that include the type of fluid being measured and the installation conditions.

  • What is a “wetted fitting”?

    A component of a metering pump or flowmeter that comes in contact with the fluid being pumped or measured is considered a WETTED FITTING or WET COMPONENT. Examples include O-ring seals, gaskets, inlet and outlet fittings, diaphragms, valve components, etc. 

  • What is a “true union”?

    The term TRUE UNION is used to define a flowmeter with double unions, on the inlet and outlet side of the flowmeter, that allow for servicing of the flowmeter, whether you are cleaning, repairing, or replacing the flowmeter. The main portion or “body” of the flowmeter can be taken out of line for ease of service without disassembling the entire system.

  • Why does the working pressure rating go down when the fluid temperature goes up?

    The properties of the materials used in the flowmeter can contribute to pressure changes with temperature. For example, certain materials used for seals, gaskets, or O-rings may experience thermal expansion or exhibit decreased elasticity at higher temperatures. This can result in leaks or reduced sealing effectiveness, leading to pressure loss.

  • What is NEMA 4X?

    NEMA 4X is a rating for enclosures that indicates they are designed to provide protection against corrosion, windblown dust and rain, splashing water, and hose-directed water.

    Click here for more information. 

Please click here to see help center disclaimers.

  • Ask me a question!
Processing... ...

Stay in the know

Request a quote

Please fill out the form to request a quote.
A sales rep will reach out to you.

To select or deselect multiple products–desktop users hold [ctrl] on Windows or [cmd] on Mac and click products.

Select Products

Pumps
Flow Meters
Skid Systems
Analyzers

Please review your selections before continuing.

Product Details
Select your industry:
How did you hear about us?

We'd like to hear from you...

ImageCatalog NumberDescriptionPriceBuy